Abb emax руководство по эксплуатации

ABB SACE Emax 2 Installation, Operation And Maintenance Instructions

  1. Manuals
  2. Brands
  3. ABB Manuals
  4. Industrial Equipment
  5. SACE Emax 2
  6. Installation, operation and maintenance instructions

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

DOC. N° 1SDH002083A1002 — ECN000119014 — Rev. A

SACE Emax 2

Emax2 E4.2 MS/DC-E low voltage air switch-disconnectors

Installation, operation and maintenance instructions for

the installer and the user

loading

Related Manuals for ABB SACE Emax 2

Summary of Contents for ABB SACE Emax 2

  • Page 1
    DOC. N° 1SDH002083A1002 — ECN000119014 — Rev. A SACE Emax 2 Emax2 E4.2 MS/DC-E low voltage air switch-disconnectors Installation, operation and maintenance instructions for the installer and the user…
  • Page 2
    ABB | SACE Emax 2 2 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A…
  • Page 3: Table Of Contents

    Putting into service and maintenance ……..38 1 — Putting into service …………38 References ………………4 Introduction ……………. 38 1 — ABB documentation mentioned in this manual ….4 General checks …………..38 Check accessories ………….. 39 Emax E4.2 circuit-breakers …………5 Final check list …………..

  • Page 4
    1SDH002083A1002 — ECN000119014 — Rev. A II | © 2021 ABB SACE Emax 2…
  • Page 5: Glossary

    ABB | SACE Emax 2 Glossary Term Description SACE Emax 2 DC New series of ABB SACE air switch disconnectors Disconnector configurations: four-pole (4P) 3 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Glossary |…

  • Page 6: References

    Technical catalog 1SDC200023D0906 Anti-insertion lock 1SDH001000R0701 Wiring diagrams 1SDM000017A1001 ABB Library Download Center ownloAD enteR Emax 2 Products RoDuCtS 4 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A References | 1 — ABB documentation mentioned in this manual…

  • Page 7: Emax E4.2 Circuit-Breakers

    All the remaining operations described in the handbook must be performed by skilled persons, in the electrical field. ABB declines all liability for damage to persons or property caused by failure to comply with the instructions in this document.

  • Page 8: Safety

    • these warnings and alarms do not include all conceivable ways to make installation, use and maintenance recommended by ABB or not, that may be made, or possible consequences and complications of each conceivable way, nor shall ABB investigate all those ways.

  • Page 9: Regulations

    ABB | SACE Emax 2 3 — Regulations Standards Sace Emax 2 MS/DC-E series circuit-breakers conform to international standards: • IEC 60947-3 • EN 60947-3 • UL 489F • UL 489B • GB/T 14048.3 They comply with the following EC directives: •…

  • Page 10: Management Operations

    ABB | SACE Emax 2 Management operations 1 — Transport and checking on receipt Introduction In view of their weight, Sace Emax 2/MS 1500 V DC series switch disconnectors require particular care during transport and handling. They are distributed with following packages: •…

  • Page 11: Identification Of Packaging

    Damage and Discrepancy If there is any damage to the packaging upon receipt and / or inconsistencies between order and product identification label or product please contact ABB. Damage to the packaging must be reported no later than Report seven days from receipt of the material.

  • Page 12: Storage Method

    WARNING! If the package with the terminals is joined to that of the circuit-breaker (UL 2500A-3200A) additional packages cannot be stacked on top. Figure 6 10 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 1 — Transport and checking on receipt…

  • Page 13: Unpacking And Handling

    Remove the packing box by lifting it upwards. See Figure 10. Figure 10 Figure 9 Continued on the next page 11 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 2 — Unpacking and handling…

  • Page 14: Disposal Of Packing Materials

    Standards Current Configuration 4000A 3200A 2500A 2000A 1600A IEC 60947-3 4000A 3200A 2500A 2000A 1600A Continued on the next page 12 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 2 — Unpacking and handling…

  • Page 15: Lift The Fixed Circuit Breaker Or The Moving Part Of A Withdrawable Circuit-Breaker

    Lift the fixed part from the base of the package using the purpose-made lifting points of the fixed part. See Figure 16. IMPORTANT: keep the lifting plates and manual until the disconnector is dismantled. 13 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 2 — Unpacking and handling…

  • Page 16: Description

    The moving and fixed parts are coupled together by special clamps installed on the movable part. Figure 18 Figure 17 Figure 19 14 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 3 — Description…

  • Page 17: Front Description

    CB open (O) / closed (I) indicator Opening pushbutton Mechanical signalling of tripped TU Closing pushbutton Springs charged-discharged signalling device Electrical data plate 15 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 3 — Description…

  • Page 18: Description Of Iec+Ccc Specification Data Plate

    UL file number Standards Rated service voltage Utilization category Admissible rated short-time current Impulse voltage Insulation voltage Rated voltage of accessories Circuit diagram 16 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 3 — Description…

  • Page 19: Description Of Ul+Iec+Ccc Specification Data Plate

    UL file number Standards Rated service voltage Utilization category Admissible rated short-time current Impulse voltage Insulation voltage Rated voltage of accessories Circuit diagram 17 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 3 — Description…

  • Page 20: Manual Operations For Opening And Closing The Circuit-Breaker

    Opening — Press the opening pushbutton “O — Push OFF” as indicated in Figure 29. Push OFF Figure 28 Figure 29 Continued on the next page 18 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 3 — Description…

  • Page 21: Mechanical Status Indicators

    • The pushbutton for enabling the insertion/extraction crank of a withdrawable circuit-breaker is pres- sed. Figure 31 Figure 32 Figure 33 Figure 34 Figure 35 19 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 3 — Description…

  • Page 22: Circuit Breaker Racking-In/Racking-Out Operations

    See Figure 39. Figure 39 Figure 38 Continued on the next page 20 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 3 — Description…

  • Page 23
    Grip the guide levers of the fixed part and push them until the moving part stops. See Figure 42. PUSH Figure 42 Continued on the next page 21 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 3 — Description…
  • Page 24
    11. Press the lock button and rotate the crank clockwise until it comes out and the indicator shows that the circuit-breaker is in CONNECT position. See Figure 46. Figure 46 Continued on the next page 22 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 3 — Description…
  • Page 25
    To extract the moving part from the fixed part, perform the same steps indicated for insertion in reverse order. Figure 49 Continued on the next page 23 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 3 — Description…
  • Page 26: Mechanical Position Indicators

    • circuit-breaker in test position (see Figure 52) • circuit-breaker in CONNECT position (see Figure 53) Figure 51 Figure 52 Figure 53 24 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 3 — Description…

  • Page 27: Environmental Conditions

    Fix the circuit-breaker to a horizontal surface using 4 x M10 screws. See Figure 54. breaker Figure 54 WARNING! Emax2 E4.2 MS/DC-E circuit-breakers can only be installed in the vertical position. 25 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 5 — Installation…

  • Page 28: Mounting Anti-Insertion Locks

    Mounting the fixed part of the Fasten the fixed part to a horizontal surface using four M8 × 25 screws. The screws are supplied by ABB. See Figure 56. Tighten the screws with tightening torque = 21 N m — 186 lb in.

  • Page 29: Types Of Terminal

    The following are the different types of terminal: 1600A IEC 1600A UL 3200A IEC 2500A UL 2000A IEC 2000A UL 4000A IEC 3200A UL 2500A IEC Figure 57 27 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 5 — Installation…

  • Page 30: Change Of Position Of The Vertical/Horizontal Terminals

    The sizing of the busbars is specified by the designer of the electrical switchgear. Figure 62 Continued on the next page 28 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 5 — Installation…

  • Page 31
    70 N m — 619.5 lb in tightening torque. NOTE: the information on the performances of the circuit-breakers in switchboards is available on the website: http://new.abb.com/low-voltage/products/circuit-breakers/emax2. 29 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 5 — Installation…
  • Page 32: Overall Dimensions

    — E4.2-E W IV 4PS H-V 2000A UL — E4.2-E W IV 2PS V 3200A UL 1SDH001001R0313 1SDH001001R0314 — E4.2-E W IV 4PS V 3200A UL 30 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 5 — Installation…

  • Page 33: Positioning Anchor Plates

    Positioning anchor plates E4.2-A 3200 A The anchor plates must be positioned as indicated in the figure. 30mm max. Bus Bracing Figure 64 31 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 5 — Installation…

  • Page 34: Grounding

    After assembly of the conductor, tighten the screw with a torque of 2 N m — 17.7 lb in. Figure 65 Figure 66 32 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Management operations | 5 — Installation…

  • Page 35: Accessories

    Overview and connection Emax 2 circuit-breakers have a set of electronic, electrical and mechanical accessories, the availability of which depends on the CB model. Consult manual 1SDH001330R1002 for details, circuit diagrams 1SDM000017A1001 and assembly instructions for the connection. 33 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Accessories | 1 — Overview…

  • Page 36: Wiring Diagrams

    Switch-disconnector for networks with negative polarity connected to earth. LOAD LOAD Diagram C — Cable entrance from below Diagram D — Cable entrance from above Continued on the next page 34 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Accessories | 2 — Wiring diagrams…

  • Page 37
    S33M/2 SPRINGS LOADED POSITION SIGNALING CONTACT Q/10 OPEN/CLOSE AUXILIARY CONTACTS OF CIRCUIT-BREAKER SWITCH — DISCONNECTOR (SECOND SET) Continued on the next page 35 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Accessories | 2 — Wiring diagrams…
  • Page 38
    24 V. Then Q5, Q6, Q7 are 400 V, while Q8, Q9, Q10 are 24 V. Always supplied with motor for loading the closing springs in Fig.13. Continued on the next page 36 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Accessories | 2 — Wiring diagrams…
  • Page 39: Mechanical Accessories

    Incompatible with YU; standard for UL version. A maximum of two accessories are available for YO and YU. Not available for withdrawable circuit-breakers with lateral fastening. 37 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Accessories | 2 — Wiring diagrams…

  • Page 40: Putting Into Service And Maintenance

    WARNING! in the presence of an undervoltage coil the circuit-breaker can be closed only after the trip unit is energized NOTE: for safety reasons, ABB strongly advises you to change the password right from the first access and to keep it with care.

  • Page 41: Check Accessories

    Result: The circuit-breaker closes correctly; the signals are normal. if present. (**) withdrawable versions only. Continued on the next page 39 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 1 — Putting into service…

  • Page 42
    85% and 110% of the rated voltage for the auxiliary accessories. auxiliary voltage if present. (**) withdrawable versions only. 40 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 1 — Putting into service…
  • Page 43: Final Check List

    — springs discharged O — OPEN and white spring signalling device DISCHARGED SPRING 41 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 1 — Putting into service…

  • Page 44: Identification Of Alarms Or Failures

    The operating mechanism is blocked Contact ABB opening pushbutton is pressed Continued on the next page 42 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 2 — Identification of alarms or failures…

  • Page 45
    The lock in open position is defective Contact ABB Continued on the next page 43 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 2 — Identification of alarms or failures…
  • Page 46: Maintenance

    ABB declines all liability for damage to persons or property caused by failure to comply with the instructions in this document. Circuit-breaker life The circuit-breakers SACE Emax 2, with or without opening or closing coils, can withstand the following operating cycles if regularly serviced. For further information see chapter 4 — Environmental conditions on page 25.

  • Page 47: Maintenance Schedule

    ABB | SACE Emax 2 Maintenance schedule Proper maintenance of the equipment allows good electromechanical operation to be maintained over time. The maintenance plan for SACE Emax 2 circuit-breakers specifies two periodic levels of maintenance for the different types of site conditions.

  • Page 48: First Level Maintenance

    46 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 4 — First level maintenance…

  • Page 49: Disassembly Operations

    If there is an undervoltage coil (G), remove it, and discharge the springs of the operating mechanism for closing and opening the circuit breaker. Figure 69 — Removing the undervoltage coil 47 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 4 — First level maintenance…

  • Page 50: Cleaning And Lubrication Of The Operating Mechanism

    NOTE: it is advisable to replace the gear motor if it has performed more than 10000 spring charging operations or reached 50% of the declared mechanical life of the circuit-breaker. 48 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 4 — First level maintenance…

  • Page 51: Final Checks

    After a trip due to a short-circuit. Figure 71 Use Mobilgrease 28, also available in the ABB greasing kit. 49 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 4 — First level maintenance…

  • Page 52: Second Level Maintenance

    Make sure that the screws that fasten the fixed part to the switchgear are well tightened (M8 — 25 N m — 221.27 lb in) 50 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 5 — Second level maintenance…

  • Page 53: Circuit-Breaker Connections And Connections Between Circuit- Breaker And Switchboard

    51 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 5 — Second level maintenance…

  • Page 54: Disassembly Operations

    Figure 76 — Removing the undervoltage coil Continued on the next page 52 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 5 — Second level maintenance…

  • Page 55
    Before cleaning and lubrication of the operating mechanism, you must remove the protection trip unit. For information about removal, see the document 1SDH001000R0523, or request the intervention of a technician ABB. 53 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 5 — Second level maintenance…
  • Page 56: Cleaning And Lubrication Of The Operating Mechanism

    Figure 80 — Lubrication of the closing hook Figure 81 — Lubrication of opening latch and shaft Continued on the next page 54 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 5 — Second level maintenance…

  • Page 57: Inspection Of Electrical And Mechanical Accessories

    NOTE: it is advisable to replace the gear motor if it has performed more than 10000 spring charging operations or reached 50% of the declared mechanical life of the circuit-breaker. 55 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 5 — Second level maintenance…

  • Page 58: Check For Wear On The Contacts

    -> OK Figure 84 — Checking the breaking gaps Close the circuit-breaker and check dimension A. Contact ABB Sace (*) if dimension A is incorrect. If dimension A is correct, open the circuit-breaker again and re-assemble the arc chutes.

  • Page 59: Final Checks

    • auxiliary contacts of the circuit-breaker, if provided. • lock for circuit-breaker in open position (key or padlock), if provided 57 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 5 — Second level maintenance…

  • Page 60: Interlock Check

    After a trip due to a short-circuit. Figure 85 Use Mobilgrease 28, also available in the ABB greasing kit. 58 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 5 — Second level maintenance…

  • Page 61: Decommissioning And Treatment At End Of Life

    ABB | SACE Emax 2 6 — Decommissioning and treatment at end of life Safety standards During the early stages of the process of decommissioning and end of life treatment of SACE Emax 2 circuit- breakers, observe the following safety rules: •…

  • Page 62
    ABB | SACE Emax 2 60 | © 2021 ABB | 1SDH002083A1002 — ECN000119014 — Rev. A Putting into service and maintenance | 6 — Decommissioning and treatment at end of life…

  1. Manuals
  2. Brands
  3. ABB Manuals
  4. Circuit breakers
  5. SACE Emax 2
  6. Manual
  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

DOC. N° 1SDH001316R1002 — ECN000086501 — Rev. A

SACE Emax 2

Emax low voltage air circuit-breakers E1.2-E2.2-E4.2-E6.2

Instructions for using Ekip Touch protection trip units

and Accessories.

Related Manuals for ABB SACE Emax 2

Summary of Contents for ABB SACE Emax 2

  • Page 1
    DOC. N° 1SDH001316R1002 — ECN000086501 — Rev. A SACE Emax 2 Emax low voltage air circuit-breakers E1.2-E2.2-E4.2-E6.2 Instructions for using Ekip Touch protection trip units and Accessories.
  • Page 2
    ABB | SACE Emax 2 2 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A…
  • Page 3: Table Of Contents

    3 — Measurement …………..48 Default ………………49 1 — Ekip TOUCH default parameters ……..49 Management operations …………50 1 — Ekip Touch maintenance and troubleshooting ….50 © 2019 ABB SACE Emax 2 | I 1SDH001316R1002 — ECN000086501 — Rev. A…

  • Page 4
    1SDH001316R1002 — ECN000086501 — Rev. A II | © 2019 ABB SACE Emax 2…
  • Page 5: Glossary

    In the event of an alarm, it commands a TRIP Ekip Touch Trip unit for SACE Emax 2 CBs, equipped with touchscreen display and available in four different versions Trip coil CB opening actuator controlled directly by Trip unit…

  • Page 6: Introduction

    ABB | SACE Emax 2 Introduction 1 — Contents Overview This manual describes the characteristics of the Ekip Touch Trip units installed on SACE Emax 2 CBs, among which: general overview: operating conditions consultation of menus for changing parameters and displaying measurements…

  • Page 7: Safety

    • anyone who is implementing procedures or using maintenance devices recommended by ABB or not must check carefully that neither their personal safety nor the safety devices are endangered by the installation, operation, maintenance method or by the tools used; contact your nearest ABB representative for further information, explanations or specific problems •…

  • Page 8: Overview Of Ekip Touch

    ABB | SACE Emax 2 Overview of Ekip Touch 1 — General characteristics Families SACE Emax 2 can be configured to operate with two Trip unit families: • Ekip Dip with interface via dip-switches • Ekip Touch with touchscreen display Both families provide protection and measuring functions related to signals from the installation and are available in different models and versions.

  • Page 9: Models And Versions

    Description Lists of the main characteristics of the protections and measurements of each package are given in the next chapters. A description of the Datalogger and Network Analyzer functions is available in manual 1SDH001330R1002. 7 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Overview of Ekip Touch | 2 — Models and Versions…

  • Page 10: Accessories And Software

    • Embedded ATS For details consult the Technical catalog or the summary documents of each function (page 9). 8 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Overview of Ekip Touch | 3 — Accessories and software…

  • Page 11
    Ekip Touch in your installation: documents NOTE: some of the documents mentioned in the next table refer to SACE Emax 2, but can also be used with SACE Tmax XT7 Ekip Connect 3…
  • Page 12
    White Paper on ATS systems for applications which require continuity of service (1SDC007115G0202) Handbook General overview of electrical installations (1SDC010002D0206) 10 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Overview of Ekip Touch | 3 — Accessories and software…
  • Page 13: Operating Features

    IMPORTANT: if connection is direct, the power supply must be galvanically insulated and provide the insulation characteristics established by standard IEC 60950 (UL 1950) or equivalent. 11 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Overview of Ekip Touch | 4 — Operating features…

  • Page 14: Interface And Menus

    Display The touchscreen display of Ekip Touch is the single-touch, color type. The touchscreen function is active when the unit is on. 12 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 1 — Presentation of interface…

  • Page 15
    IMPORTANT: only use cables supplied by ABB or with ABB accessories 13 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 1 — Presentation of interface…
  • Page 16: Navigation

    4. access one of the graphic pages: Histograms, Measuring instruments and Measurements 5. access the MENU AREA (level 3) Figure 6 Continued on the next page 14 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 2 — Navigation…

  • Page 17
    To consult a parameter, it just needs to be selected. Consult the dedicated section for instructions on how to configure and save the parameters (page 24). 15 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 2 — Navigation…
  • Page 18: Graphic

    NOTE: both pages can be set as the main page by pressing HOME, holding it for five seconds and confirming the message on the display 16 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 3 — Graphic pages…

  • Page 19
    Summary of Load Shedding measurements, if present Ekip Signalling 3T Summary of Ekip Signalling 3T module measurements, if present Continued on the next page 17 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 3 — Graphic pages…
  • Page 20
    Warning, error or prealarm About Timing due to tripped protection The complete list of alarms is given on page 50. 18 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 3 — Graphic pages…
  • Page 21: Menu

    (Set A / Set B) will be available before the list of protections available for LSIG versions available if the presence of sensor S.G.R. has been activated previously 19 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 4 — Menu…

  • Page 22
    Rc sensor Rc available when type is installed in unit and when presence of has been previously activated in Settings menu 20 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 4 — Menu…
  • Page 23
    Ekip Synchrocheck module is present available if provided for by Trip unit model or if Network Analyzer SW package has been activated 21 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 4 — Menu…
  • Page 24
    (=On) available if provided for by Trip unit model or if relative SW package has been activated available with LSIG versions 22 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 4 — Menu…
  • Page 25
    Trip unit 23 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 4 — Menu…
  • Page 26: Changing Parameters And Commands

    Abort to interrupt the save data process • • Modify to go back to the menus and change the parameter or others Figure 19 24 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 5 — Changing parameters and commands…

  • Page 27
    • if the Trip unit detects an incorrect condition, the relative details appear on the display and command execution is annulled. WARNING! aborting the programming affects all the parameters modified during the same session 25 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Interface and menus | 5 — Changing parameters and commands…
  • Page 28: Pin And Security

    Disabling The PIN code can be disabled by entering its value as: 00000; In this case, the PIN is only required to change the PIN itself in the Settings menu. Recovery if the PIN code is lost, consult document 1SDH001501R0002, available in the ABB website, or contact ABB directly.

  • Page 29: Protections

    Description Current Nominal current of the Rating plug Voltage Line-to-line voltage setting Frequency Frequency setting √3 x In x Un Power 27 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Protections | 1 — Protections — Introduction…

  • Page 30: Standard Protections

    ; Zone selectivity available with curve t=k; Block configuration available via Ekip Connect the protections do not handle the TRIP, just signaling 28 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Protections | 2 — Standard Protections…

  • Page 31
    I protection. The protection is always active; the trip threshold and time are reserved and defined by ABB. Harmonic distortion Harmonic distortion allows a monitoring alarm to be activated in the case of distorted waveforms; if enabled in the Measurements menu, the unit signals an alarm for peak factors exceeding 2.1.
  • Page 32
    (for a time set < 5 s) / ± 100 ms (for a time set ≥ 5 s) Continued on the next page 30 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Protections | 2 — Standard Protections…
  • Page 33
    ± 15 % ± 20 % (60 ms with t4 = instantaneous) ± 15 % ≤ 60 ms Other ± 20 % 31 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Protections | 2 — Standard Protections…
  • Page 34: Voltage Protections

    0.3 Un the Trip unit considers a 3% hysteresis for quitting the alarm condition 32 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Protections | 3 — Voltage protections…

  • Page 35: Voltage Advanced Protections

    Ks2 setting must ensure the following limitation: Ks2 * I21 ≥ 0.6 In; parameter Uh2 is available in the Linear mode; the setting must comply with the following limitation: Uh2 > Ul2 33 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Protections | 4 — Voltage Advanced protections…

  • Page 36: Frequency Protections

    32 V with hysteresis at 36 V tolerance valid for frequencies within range: fn ± 2%; a ± 5% tolerance is available for off range frequencies 34 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Protections | 5 — Frequency protections…

  • Page 37
    (TRIP OFF is signaled); the protection is also active for negative active power, but is independent of RP protection (Protection from inverse active power) Continued on the next page 35 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Protections | 6 — Power protections…
  • Page 38: Rocof Protections

    The function can be activated and the Set of the main protections configured in the Settings — Double Set menu; the event that determines Set change (from main to secondary) can be programmed in the Advanced — Functions menu. 36 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Protections | 8 — Adaptive protections…

  • Page 39: Additional Protections And Functions

    LOCAL Switch On Changes the configuration, from Remote to Local Settings — Modules — Functions Signaling RESET Reset the contacts of the signalling modules 37 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Protections | 8 — Adaptive protections…

  • Page 40: Measurements

    Histograms, Measuring instruments and Measurement summary pages available by activating the presence of sensor S.G.R or Rc 38 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Measurements | 1 — Standard Measurements…

  • Page 41: Ekip Measuring Measurements

    0.7 % with class 0.2 external transformers without transformers; with transformers, multiply the min and max values for the transformer ratio between primary and secondary voltages 39 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Measurements | 2 — Ekip Measuring Measurements…

  • Page 42
    Reset measurements The Energy RESET command is available in the Energy menu for the purpose of resetting the energy counters (page 21). 40 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Measurements | 2 — Ekip Measuring Measurements…
  • Page 43: Class 1 Power & Energy Metering

    CB for the specific purpose of conforming to the characteristics of the package (electronic units and internal current sensors) 41 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Measurements | 3 — Class 1 Power & Energy Metering…

  • Page 44: Settings

    Ekip Touch is supplied with the parameter setting that suits the ordered configuration. 42 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Settings | 1 — Main settings…

  • Page 45
    BLE — Connection security Activation of LV communication requires the Trip unit to be pre-engineered for a wireless connection: security of the data and LV connection between the Trip unit and its device is guaranteed thanks to the ABB EPiC application and the pairing configuration.
  • Page 46
    (trips or measurements); in the event of date and time glitches, reset and if necessary replace the battery inside Ekip Touch (page 50). 44 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Settings | 1 — Main settings…
  • Page 47: Test

    • make sure that the coils are connected to the supply source • release operation is checked by the commands: faults in Ekip Com Actuator or the coils are not detected by the test 45 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Test | 1 — Test…

  • Page 48
    (of the toroid and power supplies of the unit) and that TRIP is accomplished 46 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Test | 1 — Test…
  • Page 49: Accessories

    It is installed on a dedicated front connector and is accessible to the user for inspections or replacement following a change of model/size. For further details about the available models, operations and reference documents, consult document 1SDH001330R1002. 47 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Accessories | 1 — Introduction…

  • Page 50: Measurement

    Replacement The Measurement module can be replaced on its Trip unit, for details consult document 1SDH001330R1002. WARNING! if the Class 1 Power & Energy Metering package is present, module replacement will impair the performance values indicated on page 41; consult ABB to assess solutions able to comply with your requirements 48 | ©…

  • Page 51: Default

    1-2-3 Local bus Mode Local Language English Password 00001 Home page Histograms Led Alive Disabled View Horizontal Maintenance Test Bus 49 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Default | 1 — Ekip TOUCH default parameters…

  • Page 52: Management Operations

    Fault in Ekip Link module: check for loss of connection with one or more actors Ekip Link Bus (modules) connected to Link Bus Continued on the next page 50 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Management operations | 1 — Ekip Touch maintenance and troubleshooting…

  • Page 53
    IEEE1588 synch Synchronization problem of IEEE 1588 synchronization reference module MAC Address Ekip Com module detected with incorrect / not allowed MAC address, contact ABB. Ekip Installation Installation error between HMI and Mainboard, contact ABB Measuring Install Measurement module (Settings-Circuit breaker-Installation-Measuring-Install)
  • Page 54
    1SDH000999R0002 and 1SDH001000R0002. NOTE: check error messages on display before consulting the table; if the suggestions given fail to resolve the problem, call the ABB assistance service and provide the report produced by the Ekip Connect software if possible Fault…
  • Page 55
    Opening data not No auxiliary power supply and/or battery Correct operating condition. displayed 53 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Management operations | 1 — Ekip Touch maintenance and troubleshooting…
  • Page 56
    ABB | SACE Emax 2 54 | © 2019 ABB | 1SDH001316R1002 — ECN000086501 — Rev. A Management operations | 1 — Ekip Touch maintenance and troubleshooting…

Emax 2 идеально интегрируется в любые проекты: как в стандартные электроустановки, так и в комплексные автоматизированные системы. Воздушные автоматические выключатели Emax 2 были разработаны с целью максимального повышения эффективности работы электроустановки. Это единственный автоматический выключатель, который не только обеспечивает защитные функции, но и способен снизить потребление электроэнергии с учетом требований пользователя, что приводит к значительному сокращению потерь.

  • Эффективность и контроль
    Эксклюзивная технология управления нагрузкой позволяет добиваться существенного  сокращения энергопотребления и уменьшения расходов на электроэнергию. Встроенные мультиметры измеряют напряжение с погрешностью 0,5 %, протекающий ток с погрешностью 1 % и мощность с погрешностью 2 %. Они предназначены для мониторинга энергопотребления даже в дистанционном режиме.
  • Совместимость
    Автоматические выключатели Emax 2 идеально подходят для создания современного НКУ. Новые возможности позволяют обеспечить передачу данных по самым современным протоколам связи, включая протокол для сетей Smart Grid — МЭК 61850.
  • Исполнение
    Автоматические выключатели Emax 2 представлены в 4х типоразмерах, сочетающих в себе высокие технические характеристики и компактные габаритные размеры, оптимизированные для применений совместно с системой оболочек System pro E power. Компактные габаритные размеры аппаратов и новая конструкция силовых выводов позволяют добиться уменьшения занимаемой площади в щитовой до 25%.
  • Простота и безопасность использования
    Серия Emax 2 отличается простотой и удобством выбора при проектировании, сборке НКУ и эксплуатации в электроустановке, в сочетании с существенно возросшим функционалом аппаратов. Экономьте время сборки НКУ при использовании Emax 2: время на подключение дополнительных цепей сокращено на 15 %; время, затрачиваемое на установку дополнительных аксессуаров, уменьшено на 30 %. Сочетание систем анализа качества питающей сети, сигнализации и записи аварийных событий, самодиагностики, русскоязычного меню и отображения информации делает Emax 2 максимально удобным для конечного пользователя в процессе эксплуатации.

Инструменты и поддержка

Серии для различных сегментов

Другие предложения

  • Отправьте запрос и мы свяжемся с вами

    Свяжитесь с нами

Doc. N.° 1SDH002037A1001 — ECN000108222 — Rev. C

Emax 2

Retrotting tra interruttori estraibili Emax 2 E2.2 — E4.2 — E6.2 ed Entelliguard G Env1 — Env2 — Env3

Retrofitting kit between Emax 2 E2.2 — E4.2 — E6.2 and Entelliguard G Env1 — Env2 — Env3 Withdrawble circuit breakers

Nachrüstung zwischen ausfahrbaren Leistungsschaltern Emax 2 E2.2 — E4.2 — E6.2 und Entelliguard G Env1 — Env2 — Env3

Reconguration entre les disjoncteurs Emax 2 E2.2 -E4.2 — E6.2 et Entelliguard G Env1 — Env2 — Env3 débrochables

Reequipamiento entre los interruptores de extracción Emax 2 E2.2 — E4.2 — E6.2 y Entelliguard G Env1 — Env2 — Env3

Il presente kit di retrofitting, è costruito per la sostituzione totale di interruttori

aperti

Entelliguard G Env1 — Env2 — Env3

estraibile di più moderna fattura tipo Emax 2 di medesima taglia, senza dover

eseguire alcuna modifica alle parti attive del quadro.

E’ garantita la totale corrispondenza delle caratteristiche elettriche (corrente

nominale e potere di interruzione) a condizione che:

1.La scelta sia effettuata in conformità a quanto riportato nei cataloghi tecnici

relativi ai prodotti di retrofitting.

2.L’interruttore

Entelliguard G

proprio manuale di installazione, rispettando le distanze di isolamento verso

massa, il dimensionamento delle sbarre di connessione, il posizionamento del

primo setto di ancoraggio.

IMPORTANTE

L’attività di retrofitting consente una sostituzione di un dispositivo di comando

e protezione divenuto obsoleto ma non di alterare in maniera alcuna i dati di

progetto originali del quadro esistente. Qualora il nuovo interruttore

presentasse dati di targa superiori, i kit di retrofitting sono dimensionati per le

prestazioni del vecchio dispositivo.

Per ulteriori chiarimenti contattare ABB.

Attenzione Istruzioni riguardanti il solo assemblaggio del kit di retrotitting, non

sono da intendersi come sostitutive del manuale di installazione, uso e

manutenzione del nuovo interruttore Emax 2.

MESSA IN SICUREZZA DELL’IMPIANTO

A) A garanzia dell’incolumità del personale addetti all’installazione del kit,

prima di operare la sostituzione dell’interruttore, si raccomanda di seguire,

scrupolosamente, le seguenti azioni:

— Mettere fuori servizio il quadro ospitante

— Portare l’interruttore da sostituire in posizione di aperto e molle scariche

— Disconnettere le applicazioni ausiliarie

— Prima di estrarre l’apparecchio, controllare nuovamente il fuori servizio

dell’utenza

B) Smantellare completamente il vecchio interruttore conservando le viti di

connessione

dei terminali del vecchio interruttore

barratura del quadro.

con interruttori aperti in esecuzione

da sostituire sia installato in conformità al

Entelliguard G

This retrofitting kit allows

be fully replaced with the more modern Emax 2 plug-in air circuit-breakers of

the same size without having to modify the live parts of the switchgear in any

way.

Full correspondence of the electrical characteristics is guaranteed (rated

current and breaking capacity) so long as:

1.The kit is chosen in accordance with the indications in the technical

catalogues dedicated to retrofitting products.

2.The

Entelliguard G

circuit-breaker to be replaced has been installed in

compliance with the instructions in the relative installation manual, and with

the specified insulation clearance towards earth, connection busbar size and

position of the first anchor plate.

IMPORTANT

Retrofitting allows an obsolete control and protection device to be replaced,

but does not allow the data of the original project of the existing switchboard to

be altered in any way. If the rating plate data of the new circuit-breaker are

higher, the retrofitting kits are sized for the performance of the old device.

Consult ABB for further details.

Warning The instructions concern the sole assembly of the retrofitting kit.

They do not substitute the instructions in the installation, operation and

maintenance manual of the new Emax 2 circuit-breaker.

SETTING THE INSTALLATION IN SAFE CONDITIONS

A) To ensure that the persons who install the kit work in safe conditions, strictly

comply with the following instructions before replacing the circuit-breaker:

— Close down the switchboard in which the circuit-breaker is to be installed.

— Set the old circuit-breaker to the open position with the springs unloaded.

— Disconnect the auxiliary circuit applications.

— Check to make sure that the user is disconnected before removing the

device.

B) Completely disassemble the old circuit-breaker, but keep the screws that

connect the terminals of the old

alla

switchboard bars.

Entelliguard G Env1 — Env2 — Env3

Entelliguard G

circuit-breaker to the

circuit-breakers to

Предложите, как улучшить StudyLib

(Для жалоб на нарушения авторских прав, используйте

другую форму
)

Ваш е-мэйл

Заполните, если хотите получить ответ

Оцените наш проект

1

2

3

4

5

ABB SACE Emax 2: Available Instructions

Note for Owners:

Guidesimo.com webproject is not a service center of ABB trademark and does not carries out works for diagnosis and repair of faulty ABB SACE Emax 2 equipment. For quality services, please contact an official service center of ABB company. On our website you can read and download documentation for your ABB SACE Emax 2 device for free and familiarize yourself with the technical specifications of device.

  • ABB 5HK Series

    IB6.2.1.7DInstallation/MaintenanceInstructionsMedium-VoltagePowerCircuitBreakersType5HK1200thru3000Amperes5000VoltsJLllllMllllABBPowerDistribution,Inc.CircuitBreakerDivisionASEABROWNBOVERICourtesy of NationalSwitchgear.com …

    5HK Series Circuit breakers, 16

  • Toshiba HV6FS

    Document: GF07Z303 Rev 1INSTRUCTION MANUALINSTALLATION — OPERATION — MAINTENANCEHV6FS Vacuum Circuit Breakers – Fixed Type4.8 & 7.2kV Voltage Classes(Fast Closing)APPLICABLE MODEL NUMBERS:(Motor Operation Types)HV6FS-MUHV6FS-MLIssued: 8/2004Phone: 800.894.0412 — Fax: 888.723.4773 — Web: www.clrwtr.com — Email: [email protected] …

    HV6FS Circuit breakers, 39

  • Doepke DFS 2

    min. 50 V AC zwischen zwei aktiven Leitern zu überprüfen. Steht diese Spannung am Schalter an und leuchtet die LED nicht, so ist der Fehlerstromschutzschalter auszutauschen. Die Isolationsprüfung ist mit Prüfgeräten gemäß der DIN EN 61557-2 auszuführen. Für eine einfache Durchführung der Isolationsprüfung der elektrischen Anlage empfehlen wir die Einspeisung bei Scha …

    DFS 2 Circuit breakers, 2

  • ABB SACE Emax 2

    E1.2SACE Emax 2LEGGERE ATTENTAMENTE IL DOCUMENTO RH0100003 PRIMA DI PROCEDEREREAD CAREFULLY THE DOCUMENT RH0100003 BEFORE PROCEEDINGKit viti di fissaggio (50pz) — E1.2Fixing screws kit (50pcs) — E1.2Befestigungsschrauben (50 Stück) — E1.2Vis de fixation (50pcs) — E1.2Tornillos de fijación (50 piezas) — E1.2Doc. N.° 1SDH001399R0922 — L8926OKOK12 2 1IFISSAGGIO A PARETEWA …

    SACE Emax 2 Industrial Electrical, 4

  • Allen-Bradley 140G Series

    Phase barriers 140G-G, 140G-H, 140G-I, 140G-JSeparatori di fase Trennwande zwischen den Phasen Sèparateurs de phase Separadores de fase WARNING: To prevent electrical shock, disconnect from power source before installing or servicing. Install in suitable enclosure. Keep free from contaminants. (Follow NFPA70E requirements).AVVERTENZA: Per prevenire infortuni, togliere tensione prima dell&ap …

    140G Series Circuit breakers, 3

  • GE Spectra Series

    gSpectra Series™ Power PanelboardsType ANKN Neutrals (Model 1)WARNING: Danger of electrical shock or injury.Turn OFF power ahead of the panelboard orswitchboard before working inside theequipment or removing any component .Equipment is to be installed and maintained byproperly trained and qualified personnel only.InstallationIf a bonding strap is required for service, begin with step 1.I …

    Spectra Series Industrial Electrical, 2

  • GE AKR-4-30

         � …

    AKR-4-30 Relays, 32

  • Meiji GFCI

    Installing and testing GFCI Receptacle Please read this leaflet completely before getting started 1. What is a GFCI? A GFCI receptacle is different from conventional receptacle. In the event of a ground fault, a GFCI will trip and quickly stop the flow of electricity to prevent serious injury. Definition of Ground fault: Instead of following its normal safe path, electricity pas …

    GFCI Circuit breakers, 9

  • LS Industrial Systems Susol Series

    Leader in Electrics & AutomationSuper SolutionAir Circuit Breakers Technical CatalogSuper SolutionMeta SolutionAir Circuit Breakers Technical CatalogTechnical Catalog for Susol&Metasol ACB 2007.07 / (01) 2007.07 HUMANPOWER��HEAD OFFICEYonsei Jaedan Severance Bldg., 84-11, Namdaemunro 5-ga, Jung-gu,Seoul 100-753, KoreaTel. (82-2)2034-4870 Fax. (82-2)2034-4713��Cheong-Ju PlantCh …

    Susol Series Circuit breakers, 156

  • GE EntelliGuard GBKRKR

    1 Introduction Key Interlock Kit: The breaker key lock is an optional accessory, which will keep the breaker in trip free state while locked. Maximum 4 keys of Ronis/Profalux or Kirk type can be used. All EntelliGuard Devices can be equipped with one of the three locks, that when fitted as indicated allow the use of one to four key locks that lock the device in its open position. …

    EntelliGuard GBKRKR Circuit breakers, 4

  • ABB SACE Emax 2

    E1.2 — XT7Doc. N.° 1SDH000999R0528 — ECN000131197 — Rev. BMeasurement Enabler/Measurement Enabler with voltage socket — E1.2 — XT7SACE Emax 2 — Tmax XTInternal sockets IV with external Y connectionInternal sockets IVExternal sockets III/IVA1FInternal sockets IV Neutral on the rightOnly with code: 1SDA076244R1 — E1.2/XT7 voltage socket for neutral on the right sideBOTTOMTOPTOP BOTTOMA2B1CD1 D2Hx2I …

    SACE Emax 2 Circuit breakers, 18

  • Siemens 5ST303 Series

    Arbeitsstromauslöser / UnterspannungsauslöserShunt trip / Undervoltage ReleaseDéclencheur courant de travail / Déclencheur basse tensionBobina de disparo / Disparadores de mínima tensiónBobina a lancio di corrente / Sganciatore di minima tensioneDisparador de corrente de trabalho / Disparador de subtensãoAnma akımı deklanşörü / Düşük Gerilim RölesiРасцепитель / Расц� …

    5ST303 Series Circuit breakers, 4

  • ABB AF40

    Contactors AF and accessoriesSchütze AF und ZubehörContacteurs AF et accessoiresKontaktorer AF och tillbehörContattori AF e accessori Contactores AF y accesoriosAFABB France3, rue Jean Perrin69680 Chassieu / Francewww.abb.com/lowvoltage1SBC101036M6801 — 01/16AF40…96, CA4, CAL4, CAT4, CC4Operating instructionsBetriebsanleitungNotice d’instructionInstruktionIstruzioni tecnicheInstrucciones …

    AF40 Circuit breakers, 2

  • Camtec ESB101

    ESB101(R2) MANUAL Camtec Power Supplies GmbH — Gewerbestrasse 30 — DE-76327 Pfinztal / Germany P.1/7 (06/2016.02.4) Phone +49 (721) 46596-0 — Fax +49 (721) 46596-77 – www.camtec-gmbh.com — [email protected] (Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in …

    ESB101 Circuit breakers, 7

  • Siemens 3VA25-JP Series

    L1V30373480002-07sOperating Instructions Betriebsanleitung Notice d’utilisation Instructivo Istruzioni operativeInstruções de Serviço İşletme kılavuzu Руководство по эксплуатации Instrukcja obsługi 使用说明ENDANGERHazardous voltage. Will cause death or serious injury. Turn off and lock out all power supplying this device before working on this device. Repla …

    3VA25-JP Series Circuit breakers, 15

  • Allen-Bradley 140G-M-NVM Series

    Bul. 140G/140MG140G-M-RMX, 140G-M-NVM_, 140G-M-RVM_, 140G-N7, 140G-N8 PN-258433DIR 1000479R0612 (Version 01)Installation — Installazione — Instalación Instalação — — WARNING: To prevent electrical shock, disconnect from power source before installing or servicing. Install in suitable enclosure. Keep free from contaminants. (Follow NFPA70E requirements).AVVERTENZA: Pe …

    140G-M-NVM Series Circuit breakers, 6

  • Eaton Series NRX

    Instruction Leaet IL0131123ENEffective February 2016ContentsDescription PageGeneral information ……………………2Instructions to assemble ………………..4Installation instructions for Series NRX Type NF bus extension kit for 65 kA fixed front connect breaker Instructions apply to:Series NRX Type NF frame (front connect) ULT 489 …

    Series NRX Circuit breakers, 8

  • Vertical Power VP-X

    1 VP#X%Configurator%Release%Notes%As%of%version%1.6%(May%13,%2013)%%This%document%updated%October%31,%2013% Contents 1.! Models………………………………………………………………………………………………………………………1!2.! Updating the VP-X Pro and Sport firmware (Automatic) ………………………………………………..1!3.! Software Upgrade …

    VP-X Circuit breakers, 18

  • LEGRAND DPX

    •Notice de montage•Instruction sheet• Anweisungen • Hoja de instrucciones•Foglio istruzioni •Folha de instruções•Bycnherwbb•Instrukcje montażu•Bilgi broflürü02/2009-01 GFY3466A®•Disjoncteurs débrochables•Draw-out circuit breakers•Herausnehmbare Selbstschalter •Interruptores automáticos extraíbles•Interruttori automatici estraibili•Disjuntores extraíveis� …

    DPX Circuit breakers, 20

  • Siemens 3RV1 Series

    Phasentrennwände Phase barriers Séparateurs de phases Paredes separadoras de fase Separatori di fase Paredes de separação de fases Faz ayιrma plakasι фазовая перегородка 相间隔板 3RV1Last update: 01 January 2008A5E01621444-01Bestell-Nr. / Order No.: 3ZX1012-0RV10-8GA13RV1985-5GA0EN IEC 60947-2Technical Assistance: Telephone: +49 (0) 911-895-5900 (8°° — 17°° CET) …

    3RV1 Series Industrial Equipment, 2

  • Eaton Cutler-Hammer VCP-WR Series 18

    I.B. 8295A61H03Effective 7/97Cutler-HammerInstructions for the Use, Operation and Maintenance of TheRed Line Type VCP-WR Vacuum Circuit Breaker ElementsVCP-WR Series 29VCP-WR Series 20VCP-WR Series 18 …

    Cutler-Hammer VCP-WR Series 18 Circuit breakers, 63

  • Murr Elektronik 85057

    -(1) AllgemeinesDas Netzgerät enthält viele Besonderheiten, die bei Industrienetzgeräten zuvor nicht gegeben waren. Das Gerät ist so konstruiert,daß es die üblichen Störaussendung im Wohnbereich ausgleicht und die Störfestigkeit im Industriebereich garantiert.Das Netzgerät hat die positive Eigenschaft, größere Anlauf- und Kurzschlußströme zu liefern, so daß auch bestimmteSicherungsau …

    85057 Circuit breakers, 4

  • CHINT OUVT-1

    NO:2020.04IEC 60947-5-1OUVT-1Mounting Instructions PaigaldusjuhisedИInstrukcja montażuMontageanleitungИнструкция по монтажуInstructions de montageAsennus-ja käyttöohjeetInstruções de montagemMonteringsveiledningMontážní návodIstruzioni di montaggioнструкции за монтажInstrucciones de montajeЩодо монтуванняMontaj TalimatlarıΟδηγίες …

    OUVT-1 Circuit breakers, 6

  • Westinghouse DB-75

    InstructionsforTypesDB-75,DB-100andDBF-40AirCircuitBreakers600VoltsA-C250VoltsD-CContinuousCurrentRatingDB-75DB-1002,000Amperes2,500Amperes3,000Amperes4,000Amperes5,000Amperes[D-C6,000Amperes(OnlyWestinghouseElectricCorporationSwitchgearDivision,EastPittsburgh,Pa.I.B.33-850-4&5E,EffectiveSeptember,1976.SupersedesI.B.33-850-4&5D,November,1966.Courtesy of NationalSwitchgear.com …

    DB-75 Circuit breakers, 36

  • ABB SACE Emax 2

    E1.2-E2.2-E4.2-E6.2Sganciatore di protezione Ekip — E1.2-E2.2-E4.2-E6.2Ekip protection release — E1.2-E2.2-E4.2-E6.2 Schutzauslöser Ekip — E1.2-E2.2-E4.2-E6.2Déclencheur de protection Ekip — E1.2-E2.2-E4.2-E6.2Relé de protección Ekip — E1.2-E2.2-E4.2-E6.2SACE Emax 2Doc. N.° 1SDH001000R0508 — ECN000078285 — Rev. B12OKOK12 2 1Ekip DipEkip Touch/131/3//Ekip LCD//31CLICK …

    SACE Emax 2 Circuit breakers, 7

  • Eaton Crouse-hinds series

    DOCUMENT 1222 REVISION A July 22, 2019 Instruction Manual PRO Power Switchgear Constant Current Regulator, FAA L-828/L-829 Series 82_SGSPR-480 -_ _ — _ — _ Crouse-Hinds By EATON 1200 Kennedy Road Windsor, CT 06095 Copyright © 2019 Cooper Technologies Company …

    Crouse-hinds series Controller, 82

  • ABB S800U

    2CCC413015M0403S800U This document contains instructions for the installation and operation of S800 products, manufactured by ABB.Before installing this equipment read this instruction carefully. UNPACKING AND INSPECTIONUnpack the breaker and inspect it for any shipping damage. Insure the breaker has the proper ampere, voltage and interrupting ratings for the application. Also check breake …

    S800U Circuit breakers, 2

  • Westinghouse DBN-1016

    ( NAVSHIPS 362-2189 SWITCHBOARD Technical Manual PART Z CHAPTER 3B NAVY TYPE ACB-1600HR CIRCUIT BREAKER WESTINGHOUSE TYPE DBN-1016 BEMOVABLE ASSEMBLY 1600-AMPEBE FBAME SIZE STANDABDIZED DIMENSIONS WESTINGHOUSE ELECTRIC CORPORATION EAST PITTSBURGH, PA., U. S. A. TECHNICAL MANUAL 32-855-3Cl BUREAU OF SHIPS • NAVY DEPARTMENT • FEBRUARY, 1960 …

    DBN-1016 Circuit breakers, 47

Popular Circuit breakers User Guides:

➤ Распредилительное оборудование

Автоматы в литых корпусах:

Автоматические выключатели ABB Tmax XT.pdf ⬇

Автоматические выключатели ABB Tmax.pdf ⬇

Воздушные автоматические выключатели:

Автоматические выключатели ABB Emax.pdf ⬇

Автоматические выключатели ABB Emax X1.pdf ⬇

Автоматические выключатели ABB Emax 2.pdf ⬇

Выключатели нагрузки:

Выключатели нагрузки ABB в корпусах.pdf ⬇

Выключатели нагрузки ABB и кулачковые переключатели.pdf ⬇

Выключатель нагрузки ABB внутренней установки типа NAL.pdf ⬇

Руководство по сбору и эксплуатации выключателей нагрузки ABB типа NAL.pdf ⬇

Предохранители:

Реечные разъединители ABB InLine.pdf ⬇

Разъединители ABB EasyLine XLP.pdf ⬇

➤ Автоматика для контроля и управления

Защита электродвигателей:

Контакторы, реле перегрузки и автоматические выключатели.pdf ⬇

Частотные электроприводы:

Приводы ABB ACS355 для машиностроения.pdf ⬇

Приводы ABB ACS355 каталог.pdf ⬇

Приводы ABB ACS355 руководство по эксплуатации.pdf ⬇

Приводы ABB ACS355 руководство по монтажу.pdf ⬇

Приводы ABB ACS580 каталог 0.75..500 кВт.pdf ⬇

Приводы ABB ACS580-01 руководство по монтажу R0..R5.pdf ⬇

Приводы ABB ACS580-01 руководство по монтажу R6..R9 ⬇

Приводы ABB ACS580-01 руководство по монтажу и вводу в эксплуатацию.pdf ⬇

Приводы ABB ACS580-01 руководство по программированию и настройке.pdf ⬇

Приводы ABB ACS580-07 руководство по монтажу и вводу в эксплуатацию.pdf ⬇

Устройства плавного пуска

УПП ABB PSR-PSE-PSTX каталог.pdf ⬇

Учебное пособие по выбору и применению УПП ABB.pdf ⬇

Руководство по эксплуатации УПП ABB серии PSTX.pdf ⬇

Инструкция по эксплуатации УПП ABB PSE18..PSE370.pdf ⬇

Реле и программируемые контроллеры

Электронные изделия и реле ABB.pdf ⬇

Универсальный контроллер ABB двигателя UMC100.3.pdf ⬇

Кулачковые переключатели

Кулачковые переключатели ABB.pdf ⬇

➤ Модульное оборудование

Модульное оборудование ABB.pdf ⬇

Модульное оборудование ABB шкафы Basic M и E.pdf ⬇

Модульные контакторы ABB.pdf ⬇

Модульные контакторы поколения ESB..N/EN..N каталог.pdf ⬇

Шкафы распределительные ABB Mistral 41 каталог.pdf ⬇

Шкафы распределительные ABB Mistral 65 каталог.pdf ⬇

Шкафы распределительные ABB UK600 каталог.pdf ⬇

Шкафы распределительные ABB ComfortLine каталог.pdf ⬇

Понравилась статья? Поделить с друзьями:

А вот и еще наши интересные статьи:

  • Какого стиля руководства нет в типологии к левина
  • Тех руководство автобусов
  • Принтер canon mp520 инструкция по применению на русском
  • Динамометр эдр 20 инструкция по эксплуатации
  • Долгит в желтой упаковке инструкция по применению цена отзывы аналоги

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии